Natural gas odorizing metering pump
Today we received a customer's inquiry about electromagnetic diaphragm metering pump for natural gas odorization
The customer provided the following information:
Medium: odorization
Pressure: 3.2-3.6MPa, hourly flow rate not less than 0.5L/H, room temperature
Pump head is made of stainless steel, and the motor is explosion-proof
Parameter table of odorizing device:
Natural gas flow rate 6293~21780Nm3/h
Dosing concentration: 20mg/Nm3
Odorizing point operating pressure: 3.2~3.6MPA
Design pressure of odorizing point: 4.0Mpa
Odorizing tank volume 60L
After analysis by our technicians, the technicians said:
Electromagnetic diaphragm metering pumps cannot produce such high pressures, and conventionally they are within 8 kg
It is recommended that customers use plunger metering pumps
CX-J1-2/3.6
Flow rate 2L/H
Pressure 3.6MPA
Motor power 0.37KW-4 explosion-proof motor
Pump head material 304 stainless steel
Inlet and outlet are DN15 union connection