The customer's pump speed is fixed, and now they want to add an automatically adjustable valve at the pump outlet to control the flow rate.


Medium: Liquid medicine (without particles)

Temperature: Normal temperature

Flow range: 80~150ml/min

Export pressure: 2 kilograms

Material: 304 stainless steel

Sealing: Fluororubber

Quantity: 1-4 units

Control signal: RS485

Import and export: quick plug with diameter of 8 or 10

Is there a suitable one


Our technicians recommended it after receiving the consultation

CX-TCT911W-16P model


We recommend the CX-TCT911W-16P valve model, which fully meets all the requirements proposed by the customer. The specific compatibility

 analysis is as follows:

Material and Sealing: The valve body is made of 304 stainless steel, which is compatible with the liquid medium (particle free) and can avoid

 the risk of corrosion; Fluororubber sealing rings have strong chemical corrosion resistance and are suitable for normal temperature conditions,

 ensuring sealing reliability.

Flow and pressure: The valve flow range covers 80-150ml/min, and the outlet pressure is 2 kilograms (about 0.2MPa) lower than the nominal 

pressure of the valve, which can operate stably.

Interface and Control: The quick plug interface with diameter of 8 or 10 matches the pump outlet, making installation convenient; The RS485 

communication interface supports integration with PLC, DCS and other systems to achieve remote automation adjustment.

Functional adaptability: The valve is equipped with an electric actuator, which can adjust the valve core opening through RS485 signal and 

accurately control the flow rate; If higher stability is required, a pressure compensator (such as ZDC type) can be added to maintain a constant 

pressure difference at the flow port, further optimizing flow control.