Analysis of Magnetic Pumps for Ether Solvents
1. Customer's Requirements Recap
Media: Ether solvents (particle-free)
Viscosity: 10-20 cps (similar to water)
Flow Rate: 5 liters/minute
Temperature: Room temperature
Outlet Pressure: Not very high
2. Initial Suggestion by Customer: CX-S-6.0-88 + Variable Frequency Motor
CX-S-6.0-88 Pump Characteristics:
Typically, pumps in the CX-S series are designed for higher flow rates and pressures than what the customer requires.
The "6.0" in the model might indicate a larger displacement or flow capacity, which could be excessive for a 5 liters/minute requirement.
Using a larger pump than necessary can lead to inefficiencies, higher energy consumption, and potentially higher costs.
3. Our Recommendation: 3.2CC-88 Magnetic Drive Pump + 2-Stage Variable Frequency Motor
3.2CC-88 Pump Characteristics:
The "3.2CC" indicates a smaller displacement volume, making it more suitable for lower flow rate applications like the customer's
5 liters/minute requirement.
The pump is designed to handle clean, low-viscosity media like ether solvents efficiently.
Magnetic drive pumps are ideal for handling solvents as they eliminate the need for mechanical seals, reducing the risk of leaks and
contamination.
2-Stage Variable Frequency Motor:
A variable frequency motor allows for precise control of the pump's speed, enabling the customer to adjust the flow rate as needed.
The 2-stage configuration provides flexibility in operating conditions and can help optimize energy consumption.
4. Why Our Recommendation is More Suitable
Efficiency: The 3.2CC-88 pump is more appropriately sized for the customer's flow rate requirement, ensuring efficient operation.
Cost-Effectiveness: Using a smaller, more suitable pump can reduce initial purchase costs as well as long-term operational costs due to
lower energy consumption.
Reliability: Magnetic drive pumps are known for their reliability in handling solvents, reducing the risk of leaks and maintenance issues.
Flexibility: The variable frequency motor provides the customer with the ability to adjust the flow rate, accommodating any future
changes in process requirements.
5. Contact Information for Further Inquiries
For more detailed information on the selection and pricing of magnetic drive pumps, customers can contact Winny at CIXIFM through
the following channels:
Email: sales01@cxflowmeter.com
WhatsApp: 008618049841995
Our team is ready to provide personalized assistance and ensure that customers find the most suitable pump for their specific
application needs.

hotline
(86)021-57632436